Product facts
- Heat source
- Air
- Refrigerant
- Not recorded
- Maximum flow temperature
- Not recorded
- Backup heater
- Not recorded
- Outdoor sound power
- Not recorded
Certified seasonal efficiency of 3.41 in the average climate zone, with a design load of 13.0 kW.
All INVENTOR A.G. SINGLE MEMBER ELECTRIC APPLIANCES S.A. models
Values declared for the three climate zones and the three heating applications of the test standard. Low temperature means a 35 °C flow, medium 55 °C and high 65 °C.
| Climate zone | Application | SCOP | Seasonal efficiency | Design load (kW) | Bivalence point (°C) | Operating limit (°C) | Independently recalculated |
|---|---|---|---|---|---|---|---|
| Average | Low temperature | 4.62 | 182 % | 15.2 | -7.0 | -10.0 | 4.55 -1.5 % |
| Average | Medium temperature | 3.41 | 133 % | 13.0 | -7.0 | -10.0 | 3.37 -1.2 % |
| Colder | Low temperature | 4.02 | 158 % | 13.8 | -15.0 | -22.0 | 4.00 -0.6 % |
| Colder | Medium temperature | 3.12 | 122 % | 11.8 | -15.0 | -22.0 | 3.10 -0.8 % |
| Warmer | Low temperature | 6.33 | 248 % | 13.1 | 7.0 | 2.0 | 6.08 -4.0 % |
| Warmer | Medium temperature | 4.47 | 176 % | 14.2 | 7.0 | 2.0 | 4.38 -2.0 % |
Test points measured in the average climate zone. Each point is a measured coefficient of performance at a stated outdoor air temperature.
No measured test points are recorded for this model.
The electricity needed is the declared annual heat demand divided by the certified seasonal efficiency for that climate zone. The price is the national household electricity price in the market you choose.
Household price: €0.3618/kWh eurostat:nrg_pc_204 · Data as of 2026-10-12
| Climate zone | SCOP | Annual demand (kWh) | Electricity used | Annual cost |
|---|---|---|---|---|
| Colder | 3.12 | 9,310 | 2,984 | €1,080 |
| Average | 3.41 | 7,896 | 2,316 | €838 |
| Warmer | 4.47 | 4,236 | 948 | €343 |
A flat unit price only: standing charges, metering and time-of-use structures are excluded.
Comparable models are those whose certified design load is within 30 % of this one, which is the set a buyer would realistically substitute for it.
Certified values come from the certification file. Supplementary specifications come from the open hplib library and are only shown where a match was found.
Heat Pump KEYMARK · population dataset · CC BY 4.0
Data as of 2026-10-16